首頁>K303A-D009N-3BT>規(guī)格書詳情
K303A-D009N-3BT中文資料宏發(fā)科技數(shù)據(jù)手冊PDF規(guī)格書

廠商型號 |
K303A-D009N-3BT |
功能描述 | World Class Switching Solutions for Energy Management |
文件大小 |
243.36 Kbytes |
頁面數(shù)量 |
3 頁 |
生產(chǎn)廠商 | KG Technologies, Inc. |
企業(yè)簡稱 |
KG【宏發(fā)科技】 |
中文名稱 | 宏發(fā)科技股份有限公司官網(wǎng) |
原廠標(biāo)識 | ![]() |
數(shù)據(jù)手冊 | |
更新時間 | 2025-5-24 19:10:00 |
人工找貨 | K303A-D009N-3BT價格和庫存,歡迎聯(lián)系客服免費(fèi)人工找貨 |
K303A-D009N-3BT規(guī)格書詳情
Application Notes
Dual Coil – Positive Polarity: Place a negative connection on T2. Then apply a 50ms positive pulse to T1 to open the contacts or
to T3 to close the contacts.
Dual Coil – Negative Polarity: Place a positive connection on T2. Then apply a 50ms negative pulse to T3 to open the contacts or
to T1 to close the contacts.
Single Coil: Place a negative connection on T1. Then apply a 50ms positive pulse to T3 to close the contacts. Reversing polarity will open
the contacts.
Additional Application Notes
1: It is possible that during transit or final assembly the relay could change state. Therefore, it is recommended that all relays be set to
the desired state via a power supply.
2: In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated voltage. The pulse width should
be 50ms minimum to ensure a proper change of state. DO NOT energize both T1 and T3 at the same time on a Dual Coil or energize
the coil for longer than 1 minute (damage to the coil could incur).
3: Relays without flex-wire cannot be tin-soldered. Moving or bending the terminals could cause damage to the internal structure of
the relay.
4: For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net.